举报
快速选型
Dionex IonPac AS21 阴离子交换柱 063009
基本信息:
价格:面议
供货周期:现货
品牌:戴安
货号:

63009

 
参数规格:
具体参数见产品详情
                     
  • 产品介绍
  • 全部规格
  •      
产品介绍

Dionex IonPac AS21 阴离子交换柱

当你需要快速分离饮用水中高氯酸盐与质谱检测之前,Thermo Scientific? Dionex IonPac AS21氢氧化物选择性阴离子交换柱柱的选择。本专栏是具体列出在美国环保局的方法331。柱的容量和选择性使快速分析高氯酸盐在低μg/L浓度。此外,该2x250毫米列格式设计和LC-MS和LC-MS/MS兼容性方便使用如甲胺挥发性流动相优化



Dionex IonPac AS21 阴离子交换柱

订货信息:

分析柱
IonPac AS21 Analytical Column (2 x 250 mm)63009
保护柱
IonPac AG21 Guard Column (2 x 50 mm)63071




For Fast Analysis of Trace Perchlorate in Drinking Water Prior to Detection with MS/MS

The AS21 hydroxide-selective anion-exchange column is specifically designed for determination of trace perchlorate in drinking water prior to MS/MS detection. The capacity and selectivity enable fast analysis of perchlorate at low μg/L concentrations. The AS21 is the specified column in US EPA Method 331.0.

  • Fast separation of perchlorate prior to MS/MS detection

  • Optimized for methylamine or hydroxide mobile phases

  • Specified column for US EPA Method 331.0

  • Optimum capacity: 45 μeq per column (2 × 250 mm)

  • Operates at ambient or elevated temperatures

  • Compatible with organic solvents

The AS21 2 × 250 mm column format was specifically developed for MS/MS compatibility to allow use of volatile mobile phases such as methylamine.

 

 

IonPac AS21 Anion-Exchange Column Specifications
Dimensions:IonPac AS21 Analytical Column:
2 × 250 mm
IonPac AG21 Guard Column:
2 × 50 mm
Maximum Operating Pressure:3000 psi
Mobile Phase Compatibility:pH 0–14; 0–100% HPLC solvents
Substrate Characteristics:Bead Diameter and Pore Size:
7 μm (2 × 250 mm); super macroporous resin (2000 ?)
11 μm (2 × 50 mm); microporous resin (<1 ?)
Crosslinking (%DVB): 55%
Ion Exchange Group:Functional Group: Alkanol quaternary ammonium ion
Functional Group Characteristics:Ultralow Hydrophobicity
Capacity:45 μeq (2 × 250-mm analytical column)
1.5 μeq* (2 × 50-mm guard column)
*Guards are packed with a low-capacity microporous resin.
Column Construction:PEEK with 10–32 threaded ferrule style end fittings.
All components are nonmetallic.

Determination of perchlorate using the IonPac? AS21 and MS/MS detection.

 

IC/MS determination of perchlorate in drinking water using the IonPac AS21 column.

 

Analysis of environmental anions using the IonPac AS21 column.

Product Data Sheets
IonPac AS21 Anion-Exchange Column Data Sheet
Manuals
IonPac AS21 Analytical Column Manual
IC Column Installation QuickStart Guide