产品名称:Drinking Water
仪器厂商:Agilent/美国 安捷伦
价格:面议
库存:是
EPA Method | Application | Recommended Column | Part No. |
501, 501.3 | Measurement of trihalomethanes in drinking water GC/MS and selected ion monitoring | VF-624ms, 30 m x 0.53 mm, 3.00 μm | CP9106 |
VF-624ms, 30 m x 0.25 mm, 1.40 μm | CP9102 | ||
DB-VRX, 30 m x 0.45 mm, 2.55 μm | 124-1534 | ||
DB-624, 30 m x 0.45 mm, 2.55 μm | 124-1334 | ||
502.2 | Volatile organic compounds in water by purge and trap capillary column GC with photoionization and electrolytic conductivity detectors in series | VF-624ms, 75 m x 0.53 mm, 3.00 μm | CP9108 |
VF-624ms, 30 m x 0.53 mm, 3.00 μm | CP9106 | ||
VF-624ms, 30 m x 0.25 mm, 1.40 μm | CP9102 | ||
DB-VRX, 75 m x 0.45 mm, 2.55 μm | 124-1574 | ||
DB-624, 75 m x 0.45 mm, 2.55 μm | 124-1374 | ||
503.1 | Volatile aromatic and unsaturated organic compounds in water by purge and trap gas chromatography | DB-VRX, 30 m x 0.45 mm, 2.55 μm | 124-1534 |
DB-624, 30 m x 0.45 mm, 2.55 μm | 124-1334 | ||
504.1 | 1,2-Dibromoethane (EDB) and 1,2-dibromo-3- chloropropane (DB CP), GC, microextraction | VF-1ms, 30 m x 0.32 mm, 1.00 μm | CP8926 |
VF-1701ms, 30 m x 0.32 mm, 1.00 μm | CP9163 | ||
DB-VRX, 30 m x 0.45 mm, 2.55 μm | 124-1534 | ||
DB-624, 30 m x 0.45 mm, 2.55 μm | 124-1334 | ||
505 | Analysis of organohalide pesticides and commercial polychlorinated biphenyl (PCB) products in water by microextraction and GC | VF-1ms, 30 m x 0.32 mm, 1.00 μm | CP8926 |
VF-17ms, 30 m x 0.32 mm, 0.50 μm | CP8991 | ||
506 | Determination of phthalate and adipate esters in drinking water by liquid-liquid extraction or liquid-solid extraction and GC with photoionization detection | VF-5ms, 30 m x 0.32 mm, 0.25 μm | CP8955 |
VF-1ms, 30 m x 0.32 mm, 0.25 μm | CP8924 | ||
DB-5ms, 30 m x 0.25 mm, 0.25 μm | 122-5532 | ||
DB-5ms, 30 m x 0.53 mm, 1.50 μm | 125-5532 | ||
DB-608, 30 m x 0.53 mm, 0.50 μm | 125-6837 | ||
507 | Determination of nitrogen and phosphorus-containing pesticides in water by GC with a nitrogen-phosphorus detector | VF-5 Pesticides, 30 m x 0.25 mm, 0.25 μm | CP9074 |
VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 μm | CP9070 | ||
DB-35ms, 30 m x 0.25 mm, 0.25 μm | 122-3832 | ||
DB-5ms, 30 m x 0.25 mm, 0.25 μm | 122-5532 | ||
508 | Determination of chlorinated pesticides in water GC with an electron capture detector | VF-5 Pesticides, 30 m x 0.25 mm, 0.25 μm | CP9074 |
VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 μm | CP9070 | ||
508.1 | Determination of chlorinated pesticides, herbicides, and organohalides by liquid-solid extraction and electron capture GC | VF-5 Pesticides, 30 m x 0.25 mm, 0.25 μm | CP9074 |
DB-35ms, 30 m x 0.32 mm, 0.25 μm | 123-3832 | ||
DB-XLB, 30 m x 0.32 mm, 0.50 μm | 123-1236 |
Drinking Water CP9106/CP9102/124-1534/124-1334/CP9108/CP9106 124-1574/124-1374/124-1534/124-1334/124-1534信息由北京博德恒悦科贸有限公司为您提供,如您想了解更多关于Drinking Water CP9106/CP9102/124-1534/124-1334/CP9108/CP9106 124-1574/124-1374/124-1534/124-1334/124-1534报价、型号、参数等信息,欢迎来电或留言咨询。
除供应Drinking Water CP9106/CP9102/124-1534/124-1334/CP9108/CP9106 124-1574/124-1374/124-1534/124-1334/124-1534外,北京博德恒悦科贸有限公司还可为您提供Brownlee Validated PFP N9303601,N9303597,N9303598,N9303599,N9303600、Ion Volume EI Closed 119650-0221-T/335901-100S/335901-155S 119650-0221-T/335901-100S/335901-155S、Drinking Water CP9054/122-5533/122-1033/122-5533/122-1033/123-383 123-3832/123-1236/123-3832/CP9151/CP8944等产品,公司有专业的客户服务团队,是您值得信赖的合作伙伴。