您好,欢迎访问仪器信息网
注册
苏州市莱顿科学仪器有限公司

关注

已关注

已认证

粉丝量 0

当前位置: 莱顿仪器 > 资料中心 > 毛细柱安装快捷指南

毛细柱安装快捷指南

2009-03-11 17:07

浏览:898

分享:

资料摘要:

毛细柱安装快捷指南 Precolumn installation check list预检查清单 1.Replace oxygen, moisture, and hydrocarbon traps as needed. 如有必要,替换掉除氧、除湿、除烃的捕集阱。 2.Check gas cylinder pressure to ensure that an adequate supply of carrier, makeup, and fuel gases is available. Minimum carrier gas purity percentages: helium 99.9995, hydrogen 99.9995. 检查气瓶压力,确认载气、补充气、可燃气合适。载气纯度百分比最小应达到:氦气,99.995;氢气,99.995。 3.Clean the injector port, replace critical injection port seals, replace injection port liners, and change septa as needed. 清洗进样口,如有必要,更换密封垫,衬管,隔垫。 4.Check detector seals, and replace as necessary. Clean or replace detector jets as necessary. 检查检测器密封垫,如有必要就替换。如有必要清洗或替换检测器喷嘴。 5.Carefully inspect the column for damage or breakage. 仔细检查柱是否破损。 6.Gather the necessary installation tools: you will need a column cutter, column nuts, ferrules, a magnifying loop, and typewriter correction fluid. 收集必要的安装工具:柱切割器、柱螺母、垫圈、放大镜、打字机改正液。 Installing the column 安装柱 1.Uncoil approximately 0.5m of tubing from the column basket at both ends of the column for injector and detector installation. Avoid sharp bends in the tubing. 从柱圈两端各解开约0.5米的柱,以便进样口和检测器安装。 2.Mount the column in the oven. Use the hanging bracket if available. 在柱箱中装柱。如果可能的话,用柱悬挂架。 3.Install the column nut and Vespel or graphite ferrule at each column end; pull the nut and ferrule down the tubing approximately 5 cm 在柱两端按装螺母和Vespel或石墨垫。将螺母和垫圈顺着柱拉下约5厘米。 4.Score the column. Use a light touch to score the column about 4 to 5 cm from each end. 切割柱。距柱每个尾端约4-5cm处轻划一下。 5.Make a clean break. Grasp the column between the thumb and forefinger as close to the score point as possible. Gently pull and bend the column. The column should part easily. If the column doesn’t break easily, don’t force it! Score the column again in different place, and try for a clean break. 确保整齐的划口。用拇指和食指抓住柱,离划痕处越近越好。轻轻地弯曲柱。柱应该很容易地折断。如果柱不能折断,不能强行用力。在不同的地方再割一次柱,尝试获是整齐地划口。 6.Use a magnifying loop to inspect the cut. Make sure the cut is square across the tubing with no polyimide or glass fragments at the end of the tube. 用放大镜检查划口。确认划口正交于柱,柱端没有聚酰亚胺或石英碎片。 7.Install the column in the inlet. Check the GC manufacturer’s instrument manual for the correct insertion distance. Mark the correct distance on the column with typewriter correction fluid. Insert the column into the injector. Finger tighten the column nut until it starts to grab the column, and then tighten the nut an additional 1/4 to 1/2 turn so that the column can’t be pulled from the fitting when gentle pressure is applied. 在进样口装柱。查阅GC生产商的仪器说明书,以便获取正确的安装距离。用打字机改正液在柱子上标识正确地距离。将柱插入进样口。用手拧紧柱螺母直至其开始夹住柱子。再拧1/4-1/2圈,这样轻轻拉动时,柱子不会脱出来。 8.Turn on the carrier gas, and establish the proper flow rate. Set head pressure, split flow, and septum purge flow to appropriate levels. See Table B for nominal head pressure. If using a split/splitless inlet, check that the purge valve is ON. 接通载气,调至合适地流速。设置相应的柱头压、分流比、隔垫吹扫。常规地柱头压参考表B。如果使用分流/不分流进样口,检查分流阀是否打开。 9.Confirm carrier gas flow through the column. Immerse the end of the column in a vial of acetone and check bubbles. 确保载气通过了柱子。将柱尾端入丙酮中检查气泡。 10. Install the column in
相关产品

安捷伦7890B气相色谱仪/FID+自动进样器/现货

型号: 7890B

产地:

品牌: 安捷伦

¥ 48.9万

参考报价

相关资料

国产化恒温恒湿称重系统MWS-2适用于手动称量低浓度采样头、采样滤膜及3#滤筒。该系统集合众多领先技术,可对处理对象进行恒温恒湿平衡,并进行后续的手动称重,整个过程都在封闭洁净环境下完成,能有效防止环境微尘的污染。同时可选配射频识别(RFID)读写功能,实现系统自动编写、识别和数据统计管理。

色谱分析技术主要是应用在化学医药实验室或研究所等领域内,主要是用来分析液体或气体样品的内部成分情况。色谱柱是色谱分析系统中非常的关键的核心部件,它的作用是使得样品内部成分以不同的速率通过色谱柱,而让检测器检测通过色谱柱成分的各个不同色谱峰,最终确定其成分。下面我们来了解一下如何正确选择色谱柱。

气相色谱分析,肯定少不了“气”,就是载气。那么在气相色谱仪的使用过程中如何选择合适的载气呢?下面苏州莱顿带来气相色谱仪载气选择分析,一起来看看吧。

磐诺仪器采用静态顶空气相色谱法,基于高灵敏度氢火焰离子化检测器,对包装材 料中 12 种常用有机溶剂残留量的测定进行了系统的方法学研究,建立了一种方便,快捷,高效的检测方法。

推荐产品
供应产品

苏州市莱顿科学仪器有限公司

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 苏州市莱顿科学仪器有限公司

公司地址: 江苏省苏州市高新区运河路77号 联系人: 向先生 邮编: 215011

仪器信息网APP

展位手机站