共有 1 人回复了该问答请问怎么实现文献中的这个原位核磁实验?
 回复v2991446发表于:2020/8/27 19:39:56悬赏金额:15积分 状态:未解决
核磁小白,看到一篇原位固体核磁测反应动力学的文献,感觉对我很有用,想用他的方法,但是对他的实验不是很明白,实验部分如下:

The solid acid catalyst was H-USY zeolite (Si/Al = 11; 4.33 mmol H/g)characterized and used in a previous study.
2-methyl propane-213C(iC4-13CH) and 2-methyl propane-2d (iC4-CD) were synthesized in thelaboratory.
A 50/50 mixture of the two gases was prepared for all in situ MASNMR experiments, which showed a final composition iC4-13CH/iC4-CD/iC4-CH of 42:53:5 according to NMR analyses.
A specific homemade device was used to activate the catalyst, load the gazeous starting material, and seal the 4 mm NMR rotor without exposure to ambient atmosphere prior to each experiment.
Around 50 mg of H-USY zeolite (0.216 mmol H) was first treated at 250 °C/54h and subsequently outgassed at room temperature for 3 h (<10-7mbar),and then, 0.5 mL of the gaseous mixture iC4-13CH/iC4-CD (0.4 mmol iC4/g)was introduced.
Time resolved 1H and 13C{1H} MAS were performed on a 500 MHzBruker NMR spectrometer equipped with a conventional 4 mm MAS probehead withinthe 297-327 K temperature range.
我看我们的4mm的转子容积很小,好像上面写的是90μL,请问这0.5ml气体是怎么装进去的啊
 回复  1# Insm_bc0381a9  回复于:2021-06-14 13:04:56
如果不改动探头,需要外径刚好与4mm转子内径一致的特制玻璃管。将玻璃管接入真空系统活化催化剂,吸附标记物,在液氮保护下将玻璃管底端封口,封好的玻璃管长度要小于4mm转子,然后装入转子测试。